Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 83
Page 3-20
... temperature on its unexposed surface more than 250 ° F . ( 139 ° C . ) above its initial temperature . 3. For specimens employing steel structural members ( beams , open - web joists , etc. ) spaced more than 4 feet ( 1219 mm ) on ...
... temperature on its unexposed surface more than 250 ° F . ( 139 ° C . ) above its initial temperature . 3. For specimens employing steel structural members ( beams , open - web joists , etc. ) spaced more than 4 feet ( 1219 mm ) on ...
Page 3-51
... temperature Curve . The fire exposure of window assemblies shall be controlled to conform to the standard time - temperature curve shown in Figure 7-1-1 . 7.402.2 Furnace Temperatures . The temperatures of the test exposure shall be the ...
... temperature Curve . The fire exposure of window assemblies shall be controlled to conform to the standard time - temperature curve shown in Figure 7-1-1 . 7.402.2 Furnace Temperatures . The temperatures of the test exposure shall be the ...
Page 3-223
... temperature classification unless other temperatures are determined or unless high - temperature sprinklers are used throughout [ see Tables 4-3.1.3.2 ( a ) and ( b ) and Figure 4-3.1.3.2 on the fol- lowing pages ] . ( a ) Sprinklers in ...
... temperature classification unless other temperatures are determined or unless high - temperature sprinklers are used throughout [ see Tables 4-3.1.3.2 ( a ) and ( b ) and Figure 4-3.1.3.2 on the fol- lowing pages ] . ( a ) Sprinklers in ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood