Page 3-56
... test assembly or a minimum of 12 inches ( 300 mm ) to the furnace edge , whichever is greater . The distance between test sample ... test , condition the floor or wall assembly and test samples to provide , within a reason- able time , a ...
... test assembly or a minimum of 12 inches ( 300 mm ) to the furnace edge , whichever is greater . The distance between test sample ... test , condition the floor or wall assembly and test samples to provide , within a reason- able time , a ...
Page 3-554
... Test and Split - barrel Sampling of Soils , and for Thin - walled Tube Sampling of Soils . The sample shall be carefully identified as to origin by a boring number and sample number in conjunction with a job number , a geologic stratum ...
... Test and Split - barrel Sampling of Soils , and for Thin - walled Tube Sampling of Soils . The sample shall be carefully identified as to origin by a boring number and sample number in conjunction with a job number , a geologic stratum ...
Page 3-555
... test sample passes the No. 200 ( 75 μm ) sieve . SECTION 18.106 - PROCEDURE FOR CLASSIFICATION OF COARSE - GRAINED SOILS ( MORE THAN 50 PERCENT RETAINED ) Select test samples from the material passing the 3 - inch ( 76 mm ) sieve for ...
... test sample passes the No. 200 ( 75 μm ) sieve . SECTION 18.106 - PROCEDURE FOR CLASSIFICATION OF COARSE - GRAINED SOILS ( MORE THAN 50 PERCENT RETAINED ) Select test samples from the material passing the 3 - inch ( 76 mm ) sieve for ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood