Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 65
Page 3-720
... test runs at a 90 - degree angle to the length of the specimen . Kerfing shall extend two thirds of the way through the ply under test , and shall not penetrate the next glueline . Overlaid plywood specimens , taken as described in ...
... test runs at a 90 - degree angle to the length of the specimen . Kerfing shall extend two thirds of the way through the ply under test , and shall not penetrate the next glueline . Overlaid plywood specimens , taken as described in ...
Page 3-750
... test specimen prior to sub- jecting that specimen to an appropriate fire test . The condition simulates effects of leaching , drying and temperature such as might reasonably be anticipated on a wood element exposed to the weather over a ...
... test specimen prior to sub- jecting that specimen to an appropriate fire test . The condition simulates effects of leaching , drying and temperature such as might reasonably be anticipated on a wood element exposed to the weather over a ...
Page 3-768
... specimens . 24.206.4 Aging Tests ( for plastics used in indoor applications only . ) 24.206.4.1 Purpose . The purpose of this test is to determine whether plastic for indoor use only will successfully retain its safety characteristics ...
... specimens . 24.206.4 Aging Tests ( for plastics used in indoor applications only . ) 24.206.4.1 Purpose . The purpose of this test is to determine whether plastic for indoor use only will successfully retain its safety characteristics ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood