Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 85
Page 3-173
... tion , some of which do not recognize equipment as listed unless it is also labeled . The " authority having jurisdiction " should utilize the system employed by the listing organiza- tion to identify a listed product . Shall ...
... tion , some of which do not recognize equipment as listed unless it is also labeled . The " authority having jurisdiction " should utilize the system employed by the listing organiza- tion to identify a listed product . Shall ...
Page 3-317
... tion constructed of wood flanges and solid wood web , sup- porting a floor or roof deck . Composite wood joists may vary in depth up to 48 in . ( 1.2 m ) , may be spaced up to 48 in . ( 1.2 m ) on centers , and may span up to 60 ft ( 18 ...
... tion constructed of wood flanges and solid wood web , sup- porting a floor or roof deck . Composite wood joists may vary in depth up to 48 in . ( 1.2 m ) , may be spaced up to 48 in . ( 1.2 m ) on centers , and may span up to 60 ft ( 18 ...
Page 3-608
... tion . Minor cracks incidental to the usual method of manufacture , or minor chipping resulting from customary methods of handling in shipment and delivery , shall not be deemed grounds for rejec- tion . 21.306.2 Brick in Exposed Walls ...
... tion . Minor cracks incidental to the usual method of manufacture , or minor chipping resulting from customary methods of handling in shipment and delivery , shall not be deemed grounds for rejec- tion . 21.306.2 Brick in Exposed Walls ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood