... valve and quick - opening device are set , except where design features of the particular quick - opening device make these require- ments unnecessary . 3-2.4.3 A soft disc globe or angle valve shall be installed in the connection ...
... valve and quick - opening device are set , except where design features of the particular quick - opening device make these require- ments unnecessary . 3-2.4.3 A soft disc globe or angle valve shall be installed in the connection ...
Page 3-256
... valve shall be installed in each source of water supply . Exception : There shall be no shutoff valve in the fire department connection . 4-5.1.1.3 Valves on connections to water supplies , sec- tional control valves , and other valves ...
... valve shall be installed in each source of water supply . Exception : There shall be no shutoff valve in the fire department connection . 4-5.1.1.3 Valves on connections to water supplies , sec- tional control valves , and other valves ...
Page 3-436
... valve , an additional con- trol valve or valves at other standpipes must be shut off . The sign shall also identify the location of the additional control valves . 4-2.9.4 Where a main or sectional system control valve is located in a ...
... valve , an additional con- trol valve or valves at other standpipes must be shut off . The sign shall also identify the location of the additional control valves . 4-2.9.4 Where a main or sectional system control valve is located in a ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood