Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 79
Page 3-28
... wall or parti- tion construction . 7.206.5 Fit . The mounting of all doors shall be such that they fit snugly within the frame , against the wall surfaces , or in guides , but such mounting shall not prevent free and easy operation of ...
... wall or parti- tion construction . 7.206.5 Fit . The mounting of all doors shall be such that they fit snugly within the frame , against the wall surfaces , or in guides , but such mounting shall not prevent free and easy operation of ...
Page 3-110
... wall- board finish material is applied over an entire face of a concrete masonry wall , the equivalent thick- ness of the wall assembly shall be determined in accordance with Formula ( 13-1 ) . Equivalent thickness of units filled with ...
... wall- board finish material is applied over an entire face of a concrete masonry wall , the equivalent thick- ness of the wall assembly shall be determined in accordance with Formula ( 13-1 ) . Equivalent thickness of units filled with ...
Page 3-118
... wall thickness , 40 % solid 8 - inch unit ; 2 cells in wall thickness , 43 % solid 8 - inch unit ; 2 cells in wall thickness , 46 % solid 8 - inch unit ; 2 cells in wall thickness , 49 % solid 8 - inch unit ; 3 or 4 cells in wall ...
... wall thickness , 40 % solid 8 - inch unit ; 2 cells in wall thickness , 43 % solid 8 - inch unit ; 2 cells in wall thickness , 46 % solid 8 - inch unit ; 2 cells in wall thickness , 49 % solid 8 - inch unit ; 3 or 4 cells in wall ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood