... burner where fuel to the main burner is normally turned on and ignited automatically . BURNER , MANUALLY LIGHTED , is a burner where fuel to the main burner is turned on only by hand and ignited under supervision . Sec . 5.105 ...
... burner where fuel to the main burner is normally turned on and ignited automatically . BURNER , MANUALLY LIGHTED , is a burner where fuel to the main burner is turned on only by hand and ignited under supervision . Sec . 5.105 ...
Page 147
... burner shall Oil Pumps be a positive displacement type which automatically shuts off the oil supply when stopped . An automatic pump not an integral part of a burner shall be a listed type installed in full compliance with its listing ...
... burner shall Oil Pumps be a positive displacement type which automatically shuts off the oil supply when stopped . An automatic pump not an integral part of a burner shall be a listed type installed in full compliance with its listing ...
Page 150
... burner is located . A valve in the oil supply line operable from a location reached without passing near the burner may also be used . ( b ) Primary Safety Controls . Primary safety controls for burners shall be installed and may ...
... burner is located . A valve in the oil supply line operable from a location reached without passing near the burner may also be used . ( b ) Primary Safety Controls . Primary safety controls for burners shall be installed and may ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIHeating Ventilating and Comfort Cooling | 34 |
Copyright | |
6 other sections not shown
Other editions - View all
Common terms and phrases
550 gallons absorption unit air duct angles annealed approved automatic boiler Building Official burner BW gas vent cent circulating air supply clearance clothes dryers combustible material combustion air comfort cooling comfort heating appliance comply compressor connected connector construction Continued designed diameter Dichlorodifluoromethane discharge duct system enclosed enclosure evaporative evaporative cooler exceed flash point floor furnace fuel fuel-burning fusible plug gage galvanized steel Group 2 refrigerant heater horsepower inlet installed less liquefied petroleum gas liquid listed located machinery room Methyl Chloride minimum Occupancies Octafluorocyclobutane oil burners opening operation outlet plenum portion pounds pressure vessel refrig refrigerant piping refrigerating system roof room or space sample Section side smoke detector specified square inch Standard supply tank Table tank temperature test pressure thirty inches 30 tion Type BW gas Uniform Building Code UNIFORM MECHANICAL CODE USASI ventilation venting system Volume wall furnace warm-air furnace weight