International Conference of Building Officials. Combustion Air Openings ( Continued ) 1. Through a permanent opening or openings of the re- quired area and opening directly to the outside of the build- ing through the floor , roof , or ...
International Conference of Building Officials. Combustion Air Openings ( Continued ) 1. Through a permanent opening or openings of the re- quired area and opening directly to the outside of the build- ing through the floor , roof , or ...
Page 52
... openings or ducts be larger than the minimum sized circulat- ing air supply opening or openings as indicated by the condi- tions of listing of the furnace . ( e ) Dampers . No volume damper or volume dampers shall be placed in any warm ...
... openings or ducts be larger than the minimum sized circulat- ing air supply opening or openings as indicated by the condi- tions of listing of the furnace . ( e ) Dampers . No volume damper or volume dampers shall be placed in any warm ...
Page 54
... opening on the furnace . For the purpose of this Section a volume damper , grille , or register installed for the ... opening and pas- sageway as large as the largest piece of the furnace and in no case less than thirty inches by thirty ...
... opening on the furnace . For the purpose of this Section a volume damper , grille , or register installed for the ... opening and pas- sageway as large as the largest piece of the furnace and in no case less than thirty inches by thirty ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIHeating Ventilating and Comfort Cooling | 34 |
Copyright | |
6 other sections not shown
Other editions - View all
Common terms and phrases
550 gallons absorption unit air duct angles annealed approved automatic boiler Building Official burner BW gas vent cent circulating air supply clearance clothes dryers combustible material combustion air comfort cooling comfort heating appliance comply compressor connected connector construction Continued designed diameter Dichlorodifluoromethane discharge duct system enclosed enclosure evaporative evaporative cooler exceed flash point floor furnace fuel fuel-burning fusible plug gage galvanized steel Group 2 refrigerant heater horsepower inlet installed less liquefied petroleum gas liquid listed located machinery room Methyl Chloride minimum Occupancies Octafluorocyclobutane oil burners opening operation outlet plenum portion pounds pressure vessel refrig refrigerant piping refrigerating system roof room or space sample Section side smoke detector specified square inch Standard supply tank Table tank temperature test pressure thirty inches 30 tion Type BW gas Uniform Building Code UNIFORM MECHANICAL CODE USASI ventilation venting system Volume wall furnace warm-air furnace weight