Page 28
International Conference of Building Officials. Chapter 2 ORGANIZATION AND ENFORCEMENT Creation of Enforcement Agency Sec ... BUILDING CODE Organization and Enforcement Creation of Enforcement Agency Powers and Duties of Building Official.
International Conference of Building Officials. Chapter 2 ORGANIZATION AND ENFORCEMENT Creation of Enforcement Agency Sec ... BUILDING CODE Organization and Enforcement Creation of Enforcement Agency Powers and Duties of Building Official.
Page 32
... building . 6. Be signed by permittee , or his authorized agent , who may be required to submit evidence to indicate such authority . 7. Give such other data and information as may be required by the building official . ( b ) Plans and ...
... building . 6. Be signed by permittee , or his authorized agent , who may be required to submit evidence to indicate such authority . 7. Give such other data and information as may be required by the building official . ( b ) Plans and ...
Page 35
International Conference of Building Officials. upon written application filed by the original permittee not later ... official , and certain types of construction shall have continuous inspection by special inspectors as specified in ...
International Conference of Building Officials. upon written application filed by the original permittee not later ... official , and certain types of construction shall have continuous inspection by special inspectors as specified in ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength