Uniform Building Code |
From inside the book
Results 1-3 of 88
Page 50
... OCCUPANCY AND GENERAL REQUIREMENTS FOR ALL OCCUPANCIES Occupancy Classified Sec . 501. Every building , whether existing or hereafter erected , shall be classified by the building official , according to its use or the character of its ...
... OCCUPANCY AND GENERAL REQUIREMENTS FOR ALL OCCUPANCIES Occupancy Classified Sec . 501. Every building , whether existing or hereafter erected , shall be classified by the building official , according to its use or the character of its ...
Page 51
... occupancy shall not be located above the story or height set forth in Table No. 5 - D , except as provided in Section 507 . ( b ) Forms of Occupancy Separations . Occupancy separations shall be verti- cal or horizontal or both or , when ...
... occupancy shall not be located above the story or height set forth in Table No. 5 - D , except as provided in Section 507 . ( b ) Forms of Occupancy Separations . Occupancy separations shall be verti- cal or horizontal or both or , when ...
Page 727
... occupancy as well as an emergency use as a fallout shelter . SINGLE - PURPOSE FALLOUT SHELTER is a fallout shelter having no use or occupancy except as a fallout shelter . PROTECTION FACTOR is a factor used to express the relation ...
... occupancy as well as an emergency use as a fallout shelter . SINGLE - PURPOSE FALLOUT SHELTER is a fallout shelter having no use or occupancy except as a fallout shelter . PROTECTION FACTOR is a factor used to express the relation ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength