Page 690
... Standard Specification C73-67 of the ASTM . 24-3 ; 2403 ( d ) Concrete Building Brick . Standard Specification C55-55 of the ASTM . 24-4 ; 2403 ( e ) , Table No. 43 - B Hollow Load - bearing Concrete Masonry Units . Standard Specification ...
... Standard Specification C73-67 of the ASTM . 24-3 ; 2403 ( d ) Concrete Building Brick . Standard Specification C55-55 of the ASTM . 24-4 ; 2403 ( e ) , Table No. 43 - B Hollow Load - bearing Concrete Masonry Units . Standard Specification ...
Page 696
... Standard Specification 55 - B , October 30 , 1974 , of the Underwriters Laboratories Inc. 32-4 ; 3203 ( c ) 3 Sheet Metals . Standard Specifications A245-62aT , A361-63T and B209-63 of the ASTM . 32-5 ; 3203 ( d ) 2 , 3203 ( e ) 2 ...
... Standard Specification 55 - B , October 30 , 1974 , of the Underwriters Laboratories Inc. 32-4 ; 3203 ( c ) 3 Sheet Metals . Standard Specifications A245-62aT , A361-63T and B209-63 of the ASTM . 32-5 ; 3203 ( d ) 2 , 3203 ( e ) 2 ...
Page 698
... Standard of the International Conference of Building Officials . 43-8 ; 306 ( a ) 9 , 4303 ( e ) Thickness and ... Specification MIL - B - 19235 ( Docks ) ( December 12 , 1965 ) , and Standard Specifications of the California Lathing and ...
... Standard of the International Conference of Building Officials . 43-8 ; 306 ( a ) 9 , 4303 ( e ) Thickness and ... Specification MIL - B - 19235 ( Docks ) ( December 12 , 1965 ) , and Standard Specifications of the California Lathing and ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength