3 - A — BUILDING PERMIT FEES FEE TOTAL VALUATION $ 1 . 00 to $ 500 . 00
$ 501 . 00 to $ 2 , 000 . 00 $ 2 , 001 . 00 to $ 25 , 000 . 00 $ 25 , 001 . 00 to $ 50 ,
000 . 00 $ 10 . 00 $ 10 . 00 for the first $ 500 . 00 plus $ 1 . 50 for each additional
...
3 - A — BUILDING PERMIT FEES FEE TOTAL VALUATION $ 1 . 00 to $ 500 . 00
$ 501 . 00 to $ 2 , 000 . 00 $ 2 , 001 . 00 to $ 25 , 000 . 00 $ 25 , 001 . 00 to $ 50 ,
000 . 00 $ 10 . 00 $ 10 . 00 for the first $ 500 . 00 plus $ 1 . 50 for each additional
...
Page 91
Additional water closets shall be provided on each floor for each sex at the rate of
one for every additional 10 guests , or fractional part thereof , in excess of 10 .
Every dwelling unit shall be provided with a kitchen equipped with a kitchen sink .
Additional water closets shall be provided on each floor for each sex at the rate of
one for every additional 10 guests , or fractional part thereof , in excess of 10 .
Every dwelling unit shall be provided with a kitchen equipped with a kitchen sink .
Page 733
00 for each additional 10 , 000 cubic yards or fraction thereof . 100 , 001 to 200 ,
000 cubic yards — $ 110 . 00 for the first 100 , 000 cubic yards , plus $ 6 . 00 for
each additional 10 , 000 cubic yards or fraction thereof . 200 , 001 cubic yards or
...
00 for each additional 10 , 000 cubic yards or fraction thereof . 100 , 001 to 200 ,
000 cubic yards — $ 110 . 00 for the first 100 , 000 cubic yards , plus $ 6 . 00 for
each additional 10 , 000 cubic yards or fraction thereof . 200 , 001 cubic yards or
...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 19 |
Part Administrative | 25 |
201 | 28 |
Copyright | |
80 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending building official ceiling Chapter column compression computed concrete conform connections considered construction continuous covering Decking determined diameter direction distance Division doors effective elements equal equipment exceed EXCEPTION exit exterior walls face factor feet fire fire-resistive flexural floor foot forces Formula framing grade grain greater Group height horizontal inches increased installed joints lateral least length less limited liquids load located lumber masonry materials maximum metal nails noncombustible Occupancies one-hour openings parallel percent permitted placed portion pounds protected reinforcement resist roof rooms Select Structural separation shear side slab solid space span Special specified square feet steel storage story strength stress Structural Stud surface Table tension tests thickness Type U.B.C. Standard units values vertical walls welds wide width wire wood