Uniform Building Code |
From inside the book
Results 1-3 of 84
Page 39
... approved fabricator shall submit a Certificate of Compliance that the work was performed in accordance with the approved plans and specifications to the building official and to the engineer or architect of record . The approved ...
... approved fabricator shall submit a Certificate of Compliance that the work was performed in accordance with the approved plans and specifications to the building official and to the engineer or architect of record . The approved ...
Page 212
... approved agency . Foundation cedar or No. 2 Foundation redwood marked or branded by an approved agency may be used for sills in territories subject to moderate hazard , where termite damage is not frequent and when specifically approved ...
... approved agency . Foundation cedar or No. 2 Foundation redwood marked or branded by an approved agency may be used for sills in territories subject to moderate hazard , where termite damage is not frequent and when specifically approved ...
Page 582
... approved and shall be subject to such periodic tests as may be required . The location of all fire department hose connections shall be approved by the fire department . ( c ) Definitions . For the purpose of this chapter , certain ...
... approved and shall be subject to such periodic tests as may be required . The location of all fire department hose connections shall be approved by the fire department . ( c ) Definitions . For the purpose of this chapter , certain ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength