Uniform Building Code |
From inside the book
Results 1-3 of 15
Page 582
International Conference of Building Officials. Scope Chapter 38 FIRE - EXTINGUISHING SYSTEMS Sec . 3801. ( a ) ... automatic sprinkler systems , Classes I , II and III standpipe systems , combined systems , special automatic extinguishing ...
International Conference of Building Officials. Scope Chapter 38 FIRE - EXTINGUISHING SYSTEMS Sec . 3801. ( a ) ... automatic sprinkler systems , Classes I , II and III standpipe systems , combined systems , special automatic extinguishing ...
Page 583
International Conference of Building Officials. Automatic Fire - extinguishing Systems Sec . 3802. ( a ) Where Required . An automatic fire - extinguishing system shall be installed in the occupancies and locations as set forth in this ...
International Conference of Building Officials. Automatic Fire - extinguishing Systems Sec . 3802. ( a ) Where Required . An automatic fire - extinguishing system shall be installed in the occupancies and locations as set forth in this ...
Page 585
International Conference of Building Officials. construction , the automatic sprinkler system ... fire department , sprinklers may be omitted in rooms or areas as follows : 1 ... extinguishing systems may be installed to protect special ...
International Conference of Building Officials. construction , the automatic sprinkler system ... fire department , sprinklers may be omitted in rooms or areas as follows : 1 ... extinguishing systems may be installed to protect special ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength