Uniform Building Code |
From inside the book
Results 1-3 of 78
Page 195
... beam , inches , from the following table . depth of beam , inches . = breadth of beam , inches . EFFECTIVE LENGTH OF BEAMS TYPE OF BEAM SPAN AND NATURE OF LOAD Single - span beam , load concentrated at center Single - span beam ...
... beam , inches , from the following table . depth of beam , inches . = breadth of beam , inches . EFFECTIVE LENGTH OF BEAMS TYPE OF BEAM SPAN AND NATURE OF LOAD Single - span beam , load concentrated at center Single - span beam ...
Page 197
... Beam Span . For simple beams , the span shall be taken as the distance from face to face of supports , plus one half ... beam is continuous . ( b ) Flexure . 1. Circular cross section . A beam of circular cross section may be assumed to ...
... Beam Span . For simple beams , the span shall be taken as the distance from face to face of supports , plus one half ... beam is continuous . ( b ) Flexure . 1. Circular cross section . A beam of circular cross section may be assumed to ...
Page 198
... beams by flooring or other members may be considered and all loads within a distance from either support equal to the depth of the beam may be neglected . ( d ) Horizontal Shear in Notched Beams . Where girders , beams or joists are ...
... beams by flooring or other members may be considered and all loads within a distance from either support equal to the depth of the beam may be neglected . ( d ) Horizontal Shear in Notched Beams . Where girders , beams or joists are ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength