Uniform Building Code |
From inside the book
Results 1-3 of 87
Page 25
... Building Code , " may be cited as such and will be referred to herein as ... structure within this jurisdiction , except work located primarily in a ... Buildings and Structures.
... Building Code , " may be cited as such and will be referred to herein as ... structure within this jurisdiction , except work located primarily in a ... Buildings and Structures.
Page 26
... structural member or any part of the building or structure having required fire resistance may be made with the same materials of which the building or structure is constructed . EXCEPTION : The installation or replacement of glass ...
... structural member or any part of the building or structure having required fire resistance may be made with the same materials of which the building or structure is constructed . EXCEPTION : The installation or replacement of glass ...
Page 129
... structural element of the wall . See Sections 2312 ( j ) 2 C and 2312 ( j ) 3 A. Wind Design Sec . 2311. ( a ) General . Every building or structure and every portion thereof shall be designed and constructed to resist the wind effects ...
... structural element of the wall . See Sections 2312 ( j ) 2 C and 2312 ( j ) 3 A. Wind Design Sec . 2311. ( a ) General . Every building or structure and every portion thereof shall be designed and constructed to resist the wind effects ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength