Uniform Building Code |
From inside the book
Results 1-3 of 81
Page 25
Scope Sec. 103. The provisions of this code shall apply to the construction,
alteration, moving, demolition, repair and use of any building or structure within
this jurisdiction, except work located primarily in a public way, public utility towers
and ...
Scope Sec. 103. The provisions of this code shall apply to the construction,
alteration, moving, demolition, repair and use of any building or structure within
this jurisdiction, except work located primarily in a public way, public utility towers
and ...
Page 26
Any building plus new additions shall not exceed the height, number of stories
and area specified for new buildings. Alterations or repairs to an existing building
or structure which are nonstructural and do not adversely affect any structural ...
Any building plus new additions shall not exceed the height, number of stories
and area specified for new buildings. Alterations or repairs to an existing building
or structure which are nonstructural and do not adversely affect any structural ...
Page 129
International Conference of Building Officials. Walls and Structural Framing Sec.
2309. (a) General. Walls and structural framing shall be erected true and plumb
in accordance with the design. (b) Interior Walls. Interior walls, permanent ...
International Conference of Building Officials. Walls and Structural Framing Sec.
2309. (a) General. Walls and structural framing shall be erected true and plumb
in accordance with the design. (b) Interior Walls. Interior walls, permanent ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 19 |
Part IIDefinitions and Abbreviations | 41 |
Requirements for Group A Occupancies SEC 601 Group A Occupancies Defined | 65 |
Copyright | |
133 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved assembly automatic sprinkler system bars beam bending bolts building official building or structure ceiling Chapter column compression members compressive strength computed concrete dead load diameter distance Division doors edge exceed exit exterior walls factor fire fire-resistive construction flange flexural members foot Formula framing gauge girders grade Group grout gypsum height horizontal inches installed joints joists lath least length less live load located longitudinal masonry materials maximum metal minimum nails noncombustible occupant load one-hour fire-resistive openings panels percent permitted plastic plate plywood portland cement prestressing protected ratio resist roof rooms shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel structure studs surface Table tensile tensile stress tension tests thickness Type U.B.C. Standard unit vertical welds width wire wood wood shingles yield strength