Uniform Building Code |
From inside the book
Results 1-3 of 79
Page 92
... ceiling . Where exposed beam ceiling members are spaced at less than 48 inches on center , ceiling height shall be measured to the bottom of these members . Where exposed beam ceiling members are spaced at 48 inches or more on center ...
... ceiling . Where exposed beam ceiling members are spaced at less than 48 inches on center , ceiling height shall be measured to the bottom of these members . Where exposed beam ceiling members are spaced at 48 inches or more on center ...
Page 214
... ceiling and floor levels and at 10 - foot intervals along the length of the wall . EXCEPTION : Fire stops may be omitted at floor and ceiling levels when approved smoke - actuated fire dampers are installed at these levels . B. At all ...
... ceiling and floor levels and at 10 - foot intervals along the length of the wall . EXCEPTION : Fire stops may be omitted at floor and ceiling levels when approved smoke - actuated fire dampers are installed at these levels . B. At all ...
Page 599
... Ceilings or Roof - Ceilings Sec . 4305. ( a ) General . Fire - resistive floor - ceiling or roof - ceiling con- struction systems shall be assumed to have the fire - resistance ratings set forth in Table No. 43 - C . Penetrations in ...
... Ceilings or Roof - Ceilings Sec . 4305. ( a ) General . Fire - resistive floor - ceiling or roof - ceiling con- struction systems shall be assumed to have the fire - resistance ratings set forth in Table No. 43 - C . Penetrations in ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength