Uniform Building Code |
From inside the book
Results 1-3 of 79
Page 92
not less than 7 feet measured to the lowest projection from the ceiling . Where
exposed beam ceiling members are spaced at less than 48 inches on center ,
ceiling height shall be measured to the bottom of these members . Where
exposed ...
not less than 7 feet measured to the lowest projection from the ceiling . Where
exposed beam ceiling members are spaced at less than 48 inches on center ,
ceiling height shall be measured to the bottom of these members . Where
exposed ...
Page 214
EXCEPTION : Fire stops may be omitted at floor and ceiling levels when
approved smoke - actuated fire dampers are ... B . At all interconnections
between concealed vertical and horizontal spaces such as occur at soffits , drop
ceilings and ...
EXCEPTION : Fire stops may be omitted at floor and ceiling levels when
approved smoke - actuated fire dampers are ... B . At all interconnections
between concealed vertical and horizontal spaces such as occur at soffits , drop
ceilings and ...
Page 599
2 above , they shall be qualified by tests conducted in accordance with the
provisions of Section 4302 ( b ) . Floor - Ceilings or Root - Ceilings Sec . 4305 . (
a ) General . Fire - resistive floor - ceiling or roof - ceiling construction systems
shall be ...
2 above , they shall be qualified by tests conducted in accordance with the
provisions of Section 4302 ( b ) . Floor - Ceilings or Root - Ceilings Sec . 4305 . (
a ) General . Fire - resistive floor - ceiling or roof - ceiling construction systems
shall be ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 19 |
Part Administrative | 25 |
201 | 28 |
Copyright | |
80 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending building official ceiling Chapter column compression computed concrete conform connections considered construction continuous covering Decking determined diameter direction distance Division doors effective elements equal equipment exceed EXCEPTION exit exterior walls face factor feet fire fire-resistive flexural floor foot forces Formula framing grade grain greater Group height horizontal inches increased installed joints lateral least length less limited liquids load located lumber masonry materials maximum metal nails noncombustible Occupancies one-hour openings parallel percent permitted placed portion pounds protected reinforcement resist roof rooms Select Structural separation shear side slab solid space span Special specified square feet steel storage story strength stress Structural Stud surface Table tension tests thickness Type U.B.C. Standard units values vertical walls welds wide width wire wood