... comply with this section . Duct insulation and insulation in plenums shall conform to the requirements of the Uniform Mechan- ical Code . EXCEPTION : Roof insulation shall comply with Section 3204 . ( b ) Insulation and Covering on Pipe ...
... comply with this section . Duct insulation and insulation in plenums shall conform to the requirements of the Uniform Mechan- ical Code . EXCEPTION : Roof insulation shall comply with Section 3204 . ( b ) Insulation and Covering on Pipe ...
Page 177
... comply with the requirements of Section 2403 ( b ) . Brick used in load - bearing or shear walls shall comply with the dimension and distortion tolerances specified for Type FBS of U.B.C. Standard No. 24-1 . Where such brick do not ...
... comply with the requirements of Section 2403 ( b ) . Brick used in load - bearing or shear walls shall comply with the dimension and distortion tolerances specified for Type FBS of U.B.C. Standard No. 24-1 . Where such brick do not ...
Page 533
... comply with U.B.C. Standard No. 32-3 . Asphalt shingles shall be fastened according to manufacturer's instruc- tions ... comply with U.B.C. Standard No. 32-10 and shall be installed in an approved manner . D. Asbestos - cement shingles ...
... comply with U.B.C. Standard No. 32-3 . Asphalt shingles shall be fastened according to manufacturer's instruc- tions ... comply with U.B.C. Standard No. 32-10 and shall be installed in an approved manner . D. Asbestos - cement shingles ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength