Uniform Building Code |
From inside the book
Results 1-3 of 80
Page 154
... conform to the requirements specified in U.B.C. Standard No. 24-14 . ( i ) Stone . Natural stone shall be sound ... conform to the structural requirements for building brick of clay or shale , and glazed structural tile shall conform to ...
... conform to the requirements specified in U.B.C. Standard No. 24-14 . ( i ) Stone . Natural stone shall be sound ... conform to the structural requirements for building brick of clay or shale , and glazed structural tile shall conform to ...
Page 333
... conform to welding procedures specified in U.B.C. Standard No. 26-8 . 2. Deformed reinforcement . Deformed reinforcing bars shall conform to U.B.C. Standard No. 26-4 , except as follows : A. For A615 , A616 and A617 , yield strength ...
... conform to welding procedures specified in U.B.C. Standard No. 26-8 . 2. Deformed reinforcement . Deformed reinforcing bars shall conform to U.B.C. Standard No. 26-4 , except as follows : A. For A615 , A616 and A617 , yield strength ...
Page 334
... conform to the specification for A615 , A616 and A617 contained in U.B.C. Standard No. 26-4 , including additional requirements of Section 2603 ( f ) 2 A and the first paragraph of Section 2603 ( f ) 2 B. Smooth wire for spiral ...
... conform to the specification for A615 , A616 and A617 contained in U.B.C. Standard No. 26-4 , including additional requirements of Section 2603 ( f ) 2 A and the first paragraph of Section 2603 ( f ) 2 B. Smooth wire for spiral ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength