... CONSTRUCTION AND GENERAL REQUIREMENTS General Sec . 1701. The requirements of Part IV are for the various types of construction and represent varying degrees of public safety and resistance to fire . Every building shall be classified ...
... CONSTRUCTION AND GENERAL REQUIREMENTS General Sec . 1701. The requirements of Part IV are for the various types of construction and represent varying degrees of public safety and resistance to fire . Every building shall be classified ...
Page 116
... construction except that permanent nonbearing partitions of one - hour or two - hour fire - resistive construction , which are not part of a shaft enclosure , may have fire - retardant treated wood ( see Section 407 ) within the ...
... construction except that permanent nonbearing partitions of one - hour or two - hour fire - resistive construction , which are not part of a shaft enclosure , may have fire - retardant treated wood ( see Section 407 ) within the ...
Page 596
... construction referred to in this chapter , see the appropriate chapter in this code or the Uniform Building Code Standards specifically regulating such materials as listed in Chapter 60 . The materials and details of construction for ...
... construction referred to in this chapter , see the appropriate chapter in this code or the Uniform Building Code Standards specifically regulating such materials as listed in Chapter 60 . The materials and details of construction for ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength