Part IV REQUIREMENTS BASED ON TYPES OF CONSTRUCTION Chapter 17
CLASSIFICATION OF ALL BUILDINGS BY TYPES OF CONSTRUCTION AND
GENERAL REQUIREMENTS General Sec . 1701 . The requirements of Part IV
are ...
Part IV REQUIREMENTS BASED ON TYPES OF CONSTRUCTION Chapter 17
CLASSIFICATION OF ALL BUILDINGS BY TYPES OF CONSTRUCTION AND
GENERAL REQUIREMENTS General Sec . 1701 . The requirements of Part IV
are ...
Page 116
Walls and permanent partitions of Type II - F . R . buildings shall be of
noncombustible fire - resistive construction except that permanent nonbearing
partitions of one - hour or two - hour fire - resistive construction , which are not
part of a shaft ...
Walls and permanent partitions of Type II - F . R . buildings shall be of
noncombustible fire - resistive construction except that permanent nonbearing
partitions of one - hour or two - hour fire - resistive construction , which are not
part of a shaft ...
Page 596
In addition to all the other requirements of this code , fire - resistive materials shall
meet the requirements for fire - resistive construction given in this chapter . Fire -
resistive Materials Sec . 4302 . ( a ) General . Materials and systems used for ...
In addition to all the other requirements of this code , fire - resistive materials shall
meet the requirements for fire - resistive construction given in this chapter . Fire -
resistive Materials Sec . 4302 . ( a ) General . Materials and systems used for ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 19 |
Part Administrative | 25 |
201 | 28 |
Copyright | |
80 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending building official ceiling Chapter column compression computed concrete conform connections considered construction continuous covering Decking determined diameter direction distance Division doors effective elements equal equipment exceed EXCEPTION exit exterior walls face factor feet fire fire-resistive flexural floor foot forces Formula framing grade grain greater Group height horizontal inches increased installed joints lateral least length less limited liquids load located lumber masonry materials maximum metal nails noncombustible Occupancies one-hour openings parallel percent permitted placed portion pounds protected reinforcement resist roof rooms Select Structural separation shear side slab solid space span Special specified square feet steel storage story strength stress Structural Stud surface Table tension tests thickness Type U.B.C. Standard units values vertical walls welds wide width wire wood