... enclosure will not be required for a stairway , ramp or escalator serving only one adjacent floor and not connected ... Enclosures Smokeproof Enclosures.
... enclosure will not be required for a stairway , ramp or escalator serving only one adjacent floor and not connected ... Enclosures Smokeproof Enclosures.
Page 556
... enclosure shall exit into a public way or into an exit passageway leading to a public way . The exit passageway shall be without other openings and shall have walls , floors and ceiling of two - hour fire - resistive construction . ( d ) ...
... enclosure shall exit into a public way or into an exit passageway leading to a public way . The exit passageway shall be without other openings and shall have walls , floors and ceiling of two - hour fire - resistive construction . ( d ) ...
Page 586
... enclosure or in the case of smokeproof enclosures within the vestibule or exterior balcony , giving access to the stairway . SEE Buildings equipped with an approved automatic sprinkler system , risers and laterals which are not located ...
... enclosure or in the case of smokeproof enclosures within the vestibule or exterior balcony , giving access to the stairway . SEE Buildings equipped with an approved automatic sprinkler system , risers and laterals which are not located ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength