Page 301
... fiber in bending as listed within the table . " The allowable values listed in Table No. 25 - E for compression parallel to grain and extreme fiber in bending are based on load - sharing principles such as occur in a pile cluster . For ...
... fiber in bending as listed within the table . " The allowable values listed in Table No. 25 - E for compression parallel to grain and extreme fiber in bending are based on load - sharing principles such as occur in a pile cluster . For ...
Page 418
... fiber stress in compression B. Extreme fiber stress in tension except as permitted in .... C. Extreme fiber stress in tension at ends of simply supported members . . . . 0.60f'ci .3Vƒ'ci .6Vƒ'ci Where computed tensile stresses exceed ...
... fiber stress in compression B. Extreme fiber stress in tension except as permitted in .... C. Extreme fiber stress in tension at ends of simply supported members . . . . 0.60f'ci .3Vƒ'ci .6Vƒ'ci Where computed tensile stresses exceed ...
Page 535
... fiber felt , and Surfacing Material 400 pounds per roofing square of gravel , crushed rock , ceramic or approved ... fiber felt , or One layer of 14 - pound glass fiber felt base sheet , or combination sheet , or One layer of Type 30 ...
... fiber felt , and Surfacing Material 400 pounds per roofing square of gravel , crushed rock , ceramic or approved ... fiber felt , or One layer of 14 - pound glass fiber felt base sheet , or combination sheet , or One layer of Type 30 ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength