Uniform Building Code |
From inside the book
Results 1-3 of 83
Page 51
... fire - resistive , " " three - hour fire - resistive , " " two - hour fire - resis- tive , " and " one - hour fire - resistive . " ( See U.B.C. Standard No. 43-7 for fire dampers in air ducts piercing occupancy separations . ) 1. A ...
... fire - resistive , " " three - hour fire - resistive , " " two - hour fire - resis- tive , " and " one - hour fire - resistive . " ( See U.B.C. Standard No. 43-7 for fire dampers in air ducts piercing occupancy separations . ) 1. A ...
Page 582
... fire - extinguishing systems required in this code shall be installed in accordance with the requirements of this chapter . Fire hose threads used in connection with fire - extinguishing systems shall be National Standard hose thread or ...
... fire - extinguishing systems required in this code shall be installed in accordance with the requirements of this chapter . Fire hose threads used in connection with fire - extinguishing systems shall be National Standard hose thread or ...
Page 601
... Fire - resistive Tests . The fire - protection rating of all types of required fire assemblies shall be determined in accordance with the requirements specified in U.B.C. Standards No. 43-2 and No. 43-4 . ( f ) Hardware . Every fire ...
... Fire - resistive Tests . The fire - protection rating of all types of required fire assemblies shall be determined in accordance with the requirements specified in U.B.C. Standards No. 43-2 and No. 43-4 . ( f ) Hardware . Every fire ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength