Page 51
... fire - resistive construction . ( c ) Types of Occupancy Separations . Occupancy separations shall be classed as " four - hour fire - resistive , " " three - hour fire - resistive , " " two - hour fire - resis- tive , " and " one - hour ...
... fire - resistive construction . ( c ) Types of Occupancy Separations . Occupancy separations shall be classed as " four - hour fire - resistive , " " three - hour fire - resistive , " " two - hour fire - resis- tive , " and " one - hour ...
Page 116
... fire - resistive construction except that permanent nonbearing partitions of one - hour or two - hour fire - resistive construction , which are not part of a shaft enclosure , may have fire - retardant treated wood ( see Section 407 ) ...
... fire - resistive construction except that permanent nonbearing partitions of one - hour or two - hour fire - resistive construction , which are not part of a shaft enclosure , may have fire - retardant treated wood ( see Section 407 ) ...
Page 596
International Conference of Building Officials. Chapter 43 FIRE - RESISTIVE STANDARDS General Sec . 4301. In addition to all the other requirements of this code , fire - resistive materials shall meet the requirements for fire - resistive ...
International Conference of Building Officials. Chapter 43 FIRE - RESISTIVE STANDARDS General Sec . 4301. In addition to all the other requirements of this code , fire - resistive materials shall meet the requirements for fire - resistive ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength