Uniform Building Code |
From inside the book
Results 1-3 of 82
Page 53
... area separation wall need only extend through the concealed space to the outer edges of the projecting elements . The exterior walls and the projecting elements above shall be 53 1982 EDITION 504-505 Allowable Floor Areas.
... area separation wall need only extend through the concealed space to the outer edges of the projecting elements . The exterior walls and the projecting elements above shall be 53 1982 EDITION 504-505 Allowable Floor Areas.
Page 92
... area thereof , but in no case shall the height of the furred ceiling be less than 7 feet . ( b ) Floor Area . Every dwelling unit shall have at least one room which shall have not less than 150 square feet of floor area . Other ...
... area thereof , but in no case shall the height of the furred ceiling be less than 7 feet . ( b ) Floor Area . Every dwelling unit shall have at least one room which shall have not less than 150 square feet of floor area . Other ...
Page 584
International Conference of Building Officials. space below or over a stairway in Group A , Divisions 2 , 2.1 , 3 and 4 Occupan- cies . See Section 3309 ( f ) . 5. Other areas . An automatic sprinkler system shall be installed in specific ...
International Conference of Building Officials. space below or over a stairway in Group A , Divisions 2 , 2.1 , 3 and 4 Occupan- cies . See Section 3309 ( f ) . 5. Other areas . An automatic sprinkler system shall be installed in specific ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength