Uniform Building Code |
From inside the book
Results 1-3 of 85
Page 293
SGrade designations are as follows : Visually Graded Southern Pine Ll is Li
laminating grade ( dense for Douglas fir - larch ) . LID is LI dense laminating
grade for hem - fir . LICL is Ll close grain laminating grade . L2D is L2 laminating
grade ...
SGrade designations are as follows : Visually Graded Southern Pine Ll is Li
laminating grade ( dense for Douglas fir - larch ) . LID is LI dense laminating
grade for hem - fir . LICL is Ll close grain laminating grade . L2D is L2 laminating
grade ...
Page 294
( Continued ) Visually Graded Southern Pine SSD is dense select structural ,
structural joists and planks , or structural light framing grade ( dense ) . NID is No .
1 dense structural joists and planks , or structural light framing grade or No .
( Continued ) Visually Graded Southern Pine SSD is dense select structural ,
structural joists and planks , or structural light framing grade ( dense ) . NID is No .
1 dense structural joists and planks , or structural light framing grade or No .
Page 730
AS - GRADED is the extent of surface conditions on completion of grading . ...
BORROW is earth material acquired from an off - site location for use in grading
on a site . ... GRADE shall mean the vertical location of the ground surface .
Existing ...
AS - GRADED is the extent of surface conditions on completion of grading . ...
BORROW is earth material acquired from an off - site location for use in grading
on a site . ... GRADE shall mean the vertical location of the ground surface .
Existing ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 19 |
Part Administrative | 25 |
201 | 28 |
Copyright | |
80 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending building official ceiling Chapter column compression computed concrete conform connections considered construction continuous covering Decking determined diameter direction distance Division doors effective elements equal equipment exceed EXCEPTION exit exterior walls face factor feet fire fire-resistive flexural floor foot forces Formula framing grade grain greater Group height horizontal inches increased installed joints lateral least length less limited liquids load located lumber masonry materials maximum metal nails noncombustible Occupancies one-hour openings parallel percent permitted placed portion pounds protected reinforcement resist roof rooms Select Structural separation shear side slab solid space span Special specified square feet steel storage story strength stress Structural Stud surface Table tension tests thickness Type U.B.C. Standard units values vertical walls welds wide width wire wood