Page 269
... inches and wider , 2 inches to 4 inches thick ( and 21⁄2 inches to 4 inches thick ) size classifications apply to 5 - inch and 6 - inch widths only , for grades of Select Structural , No. 1 , No. 2 , No. 3 , Appearance and Stud ...
... inches and wider , 2 inches to 4 inches thick ( and 21⁄2 inches to 4 inches thick ) size classifications apply to 5 - inch and 6 - inch widths only , for grades of Select Structural , No. 1 , No. 2 , No. 3 , Appearance and Stud ...
Page 527
... inches on center or by barbed galvanized nails at 6 inches on center with a 18- inch minimum penetration . The galvanized wire mesh may be attached to steel studs by equivalent wire ties . If this method is applied over solid sheathing ...
... inches on center or by barbed galvanized nails at 6 inches on center with a 18- inch minimum penetration . The galvanized wire mesh may be attached to steel studs by equivalent wire ties . If this method is applied over solid sheathing ...
Page 537
... inch plywood with exterior glue or 1- inch nominal T and G boards , overlaid with a layer of approved asbestos felt lapped 2 inches on the horizontal and vertical joints . An 18 - inch - wide strip of the same asbestos felt shall be ...
... inch plywood with exterior glue or 1- inch nominal T and G boards , overlaid with a layer of approved asbestos felt lapped 2 inches on the horizontal and vertical joints . An 18 - inch - wide strip of the same asbestos felt shall be ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength