Page 537
... installed with plies laid parallel to the slope of the deck , and the surfacing material shall be other than gravel or slag . 2. Asphalt shingles laid with double coverage may be installed on slopes as low as 2 inches in 12 inches ...
... installed with plies laid parallel to the slope of the deck , and the surfacing material shall be other than gravel or slag . 2. Asphalt shingles laid with double coverage may be installed on slopes as low as 2 inches in 12 inches ...
Page 583
... installed in the occupancies and locations as set forth in this section . For special provisions on hazardous chemicals and magnesium , and calcium carbide , see the Fire Code . ( b ) All Occupancies Except Group R , Division 3 and ...
... installed in the occupancies and locations as set forth in this section . For special provisions on hazardous chemicals and magnesium , and calcium carbide , see the Fire Code . ( b ) All Occupancies Except Group R , Division 3 and ...
Page 584
... installed in specific areas of Group A Occupancies as follows : Under the roof and gridiron , in the tie and fly galleries and in all places behind the proscenium wall of stages ; over enclosed platforms in excess of 500 square feet in ...
... installed in specific areas of Group A Occupancies as follows : Under the roof and gridiron , in the tie and fly galleries and in all places behind the proscenium wall of stages ; over enclosed platforms in excess of 500 square feet in ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength