Uniform Building Code |
From inside the book
Results 1-3 of 43
Page 651
... lath , and the gauge and spacing of wire in welded or woven lath , the spacing of supports , and the methods of attachment to wood supports shall be as set forth in Tables No. 47 - B and No. 47 - C . Metal lath shall be attached to ...
... lath , and the gauge and spacing of wire in welded or woven lath , the spacing of supports , and the methods of attachment to wood supports shall be as set forth in Tables No. 47 - B and No. 47 - C . Metal lath shall be attached to ...
Page 661
... lath , wire lath , wire fabric lath and metal accessories shall conform with the provisions of U.B.C. Standard No. 47-4 . Gypsum lath shall conform with the provisions of U.B.C. Standard No. 47-8 . 2Metal lath and wire fabric lath used ...
... lath , wire lath , wire fabric lath and metal accessories shall conform with the provisions of U.B.C. Standard No. 47-4 . Gypsum lath shall conform with the provisions of U.B.C. Standard No. 47-8 . 2Metal lath and wire fabric lath used ...
Page 663
... Lath 1 % " No. 13 gauge 1 " head , blued 810 810 810 10 8 16 6.1⁄2 " Gypsum Lath 1/4 " No. 13 gauge 3/4 7 % 810 8 10 19/64 " head , blued 8 8 10 611 810 810 611 16 34 1 % 810 810 611 664 PLASTER BASE 1. Expanded Metal Lath 2. Wire ...
... Lath 1 % " No. 13 gauge 1 " head , blued 810 810 810 10 8 16 6.1⁄2 " Gypsum Lath 1/4 " No. 13 gauge 3/4 7 % 810 8 10 19/64 " head , blued 8 8 10 611 810 810 611 16 34 1 % 810 810 611 664 PLASTER BASE 1. Expanded Metal Lath 2. Wire ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength