Page 59
... 603 ) DESCRIPTION OF OCCUPANCY 1 - Any assembly building with a stage
and an occupant load of 1000 or more in the building 2 — Any building or portion
of a building having an assembly room with an occupant load of less than 1000 ...
... 603 ) DESCRIPTION OF OCCUPANCY 1 - Any assembly building with a stage
and an occupant load of 1000 or more in the building 2 — Any building or portion
of a building having an assembly room with an occupant load of less than 1000 ...
Page 60
flammable liquids Protected less than 20 feet Open parking garages ( For
requirements , See Section 709 . ) Heliports 4 Ice plants , power plants , pumping
plants , cold storage and creameries 1 hour less than 5 feet Not permitted less
than ...
flammable liquids Protected less than 20 feet Open parking garages ( For
requirements , See Section 709 . ) Heliports 4 Ice plants , power plants , pumping
plants , cold storage and creameries 1 hour less than 5 feet Not permitted less
than ...
Page 121
Wood columns may be of sawn timber or structural gluedlaminated timber not
less than 8 inches in any dimension when supporting roof or floor loads except
as specified in Section 2106 ( d ) . Columns shall be continuous or superimposed
...
Wood columns may be of sawn timber or structural gluedlaminated timber not
less than 8 inches in any dimension when supporting roof or floor loads except
as specified in Section 2106 ( d ) . Columns shall be continuous or superimposed
...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 19 |
Part Administrative | 25 |
201 | 28 |
Copyright | |
80 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending building official ceiling Chapter column compression computed concrete conform connections considered construction continuous covering Decking determined diameter direction distance Division doors effective elements equal equipment exceed EXCEPTION exit exterior walls face factor feet fire fire-resistive flexural floor foot forces Formula framing grade grain greater Group height horizontal inches increased installed joints lateral least length less limited liquids load located lumber masonry materials maximum metal nails noncombustible Occupancies one-hour openings parallel percent permitted placed portion pounds protected reinforcement resist roof rooms Select Structural separation shear side slab solid space span Special specified square feet steel storage story strength stress Structural Stud surface Table tension tests thickness Type U.B.C. Standard units values vertical walls welds wide width wire wood