... liquid " is both flammable and combus- tible liquids . LIQUID STORAGE ROOM is a Group H , Division 2 Occupancy in which the quantities of flammable or combustible liquids do not exceed the limits set forth in the Fire Code . LIQUID ...
... liquid " is both flammable and combus- tible liquids . LIQUID STORAGE ROOM is a Group H , Division 2 Occupancy in which the quantities of flammable or combustible liquids do not exceed the limits set forth in the Fire Code . LIQUID ...
Page 80
... Liquid storage rooms . The design and con- struction of liquid storage rooms in which Class I , II or III - A liquids are stored shall be in accordance with the requirements for a Group H , Division 2 Occupan- cy and the following : A ...
... Liquid storage rooms . The design and con- struction of liquid storage rooms in which Class I , II or III - A liquids are stored shall be in accordance with the requirements for a Group H , Division 2 Occupan- cy and the following : A ...
Page 84
... LIQUIDS AND CHEMICALS MATERIAL 1. Flammable liquids ' Class I - A Class I - B Class I - C 2. Combustible liquids ' Class II Class III - A 3. Combination flammable liquids3 4. Flammable gases 5. Liquefied flammable gases 6. Flammable ...
... LIQUIDS AND CHEMICALS MATERIAL 1. Flammable liquids ' Class I - A Class I - B Class I - C 2. Combustible liquids ' Class II Class III - A 3. Combination flammable liquids3 4. Flammable gases 5. Liquefied flammable gases 6. Flammable ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength