... lumber may be used interchangeably with solid - sawn members of the same species and grade . Such use shall include , but not be limited to , light framing joists , planks and decking . Plywood shall be of species Group 1 , 2 , 3 or 4 ...
... lumber may be used interchangeably with solid - sawn members of the same species and grade . Such use shall include , but not be limited to , light framing joists , planks and decking . Plywood shall be of species Group 1 , 2 , 3 or 4 ...
Page 191
International Conference of Building Officials. GRADE ( Lumber ) , the classification of lumber in regard to strength and utility in accordance with the grading rules of an approved lumber grading agency . HARDBOARD is a fibrous - felted ...
International Conference of Building Officials. GRADE ( Lumber ) , the classification of lumber in regard to strength and utility in accordance with the grading rules of an approved lumber grading agency . HARDBOARD is a fibrous - felted ...
Page 267
... lumber the DRY surfaced size shall be used . In calculating design values , the natural gain in strength and stiffness that occurs as lumber dries has been taken into consideration as well as the reduction in size that occurs when ...
... lumber the DRY surfaced size shall be used . In calculating design values , the natural gain in strength and stiffness that occurs as lumber dries has been taken into consideration as well as the reduction in size that occurs when ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength