... Openings and Partitions Sec . 2003. ( a ) Exterior Walls . Exterior walls shall be constructed of noncom- bustible ... openings are permitted and noncombustible two - hour fire resistive where protection of openings is required . 3. In ...
... Openings and Partitions Sec . 2003. ( a ) Exterior Walls . Exterior walls shall be constructed of noncom- bustible ... openings are permitted and noncombustible two - hour fire resistive where protection of openings is required . 3. In ...
Page 120
... Openings and Partitions Sec . 2103. ( a ) Exterior Walls . Exterior walls shall be constructed of noncom- bustible ... openings are permitted and noncombustible two - hour fire resistive where protection of openings is required . 3. In ...
... Openings and Partitions Sec . 2103. ( a ) Exterior Walls . Exterior walls shall be constructed of noncom- bustible ... openings are permitted and noncombustible two - hour fire resistive where protection of openings is required . 3. In ...
Page 601
... opening and one on each side of the wall at the ceiling height where the ceiling is more than 3 feet above the opening . be Fire assemblies protecting openings required to have one and one - half , one or three - fourths - hour fire ...
... opening and one on each side of the wall at the ceiling height where the ceiling is more than 3 feet above the opening . be Fire assemblies protecting openings required to have one and one - half , one or three - fourths - hour fire ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength