... panels . 2. The fire department communications panel . 3. Fire detection and alarm system annunciator panels . 4. Annunciator visually indicating the location of the elevators and whether they are operational . 5. Status indicators and ...
... panels . 2. The fire department communications panel . 3. Fire detection and alarm system annunciator panels . 4. Annunciator visually indicating the location of the elevators and whether they are operational . 5. Status indicators and ...
Page 677
... Panels . Combinations of plastic glazing and plastic exterior wall panels shall be subject to the area , height , percentage and separation requirements applicable to the class of plastics as prescribed for wall panel installation . ( e ) ...
... Panels . Combinations of plastic glazing and plastic exterior wall panels shall be subject to the area , height , percentage and separation requirements applicable to the class of plastics as prescribed for wall panel installation . ( e ) ...
Page 679
... panels in the exterior wall and the maximum square feet of any individual panel may be increased 50 percent above that set forth in Table No. 52 - A , and the separation requirements , both vertical and horizontal , as set forth in ...
... panels in the exterior wall and the maximum square feet of any individual panel may be increased 50 percent above that set forth in Table No. 52 - A , and the separation requirements , both vertical and horizontal , as set forth in ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength