Page 190
... Particleboard shall conform to U.B.C. Standard No. 25-25 . Approved fire - retardant treated wood shall be dried , following treatment , to a maximum moisture content as follows : solid - sawn lumber 2 inches in thickness or less to 19 ...
... Particleboard shall conform to U.B.C. Standard No. 25-25 . Approved fire - retardant treated wood shall be dried , following treatment , to a maximum moisture content as follows : solid - sawn lumber 2 inches in thickness or less to 19 ...
Page 217
... particleboard sheathing , joints shall occur over framing members and shall be covered with a continuous wood batt ; or joints shall be lapped horizontally or otherwise made waterproof to the satisfaction of the building official ...
... particleboard sheathing , joints shall occur over framing members and shall be covered with a continuous wood batt ; or joints shall be lapped horizontally or otherwise made waterproof to the satisfaction of the building official ...
Page 221
International Conference of Building Officials. ( f ) Particleboard Underlayment . Particleboard floor underlayment shall con- form to Type 1 - M grades of U.B.C. Standard No. 25-25 . Underlayment shall be not less than 1/4 inch in ...
International Conference of Building Officials. ( f ) Particleboard Underlayment . Particleboard floor underlayment shall con- form to Type 1 - M grades of U.B.C. Standard No. 25-25 . Underlayment shall be not less than 1/4 inch in ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength