Uniform Building Code |
From inside the book
Results 1-3 of 63
Page 613
... Plastered each side with " gypsum plaster . S 16 Two cells in wall thickness , units at least 40 percent solid . Plastered one side with % " gypsum plaster . 82 Hollow Clay 18 Three cells in wall thickness , units at least 40 percent ...
... Plastered each side with " gypsum plaster . S 16 Two cells in wall thickness , units at least 40 percent solid . Plastered one side with % " gypsum plaster . 82 Hollow Clay 18 Three cells in wall thickness , units at least 40 percent ...
Page 616
... plaster on one side . 42 Solid Gypsum Plaster 43 44 45 46 17 47 3/4 " by No. 16 gauge vertical cold - rolled channels , 16 " on center with 2.5 - pound flat metal lath applied to one face and tied with No. 18 gauge wire at 6 " spacing ...
... plaster on one side . 42 Solid Gypsum Plaster 43 44 45 46 17 47 3/4 " by No. 16 gauge vertical cold - rolled channels , 16 " on center with 2.5 - pound flat metal lath applied to one face and tied with No. 18 gauge wire at 6 " spacing ...
Page 619
... plaster mixed 1 : 1 by weight gypsum to sand aggregate applied on 3.4 pound metal lath wire tied to studs , each side . 3/4 " plaster applied over each face , including finish coat . 41⁄444 ( Continued ) 620 920 TABLE NO . 43 - B ...
... plaster mixed 1 : 1 by weight gypsum to sand aggregate applied on 3.4 pound metal lath wire tied to studs , each side . 3/4 " plaster applied over each face , including finish coat . 41⁄444 ( Continued ) 620 920 TABLE NO . 43 - B ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength