Uniform Building Code |
From inside the book
Results 1-3 of 83
Page 44
FLOOR AREA is the area included within the surrounding exterior walls of a
building or portion thereof , exclusive of vent shafts and courts . The floor area of
a building , or portion thereof , not provided with surrounding exterior walls shall
be ...
FLOOR AREA is the area included within the surrounding exterior walls of a
building or portion thereof , exclusive of vent shafts and courts . The floor area of
a building , or portion thereof , not provided with surrounding exterior walls shall
be ...
Page 65
Any building or portion of a building having an assembly room with an occupant
load of less than 1000 and a stage . Division 2 . 1 . Any building or portion of a
building having an assembly room with an occupant load of 300 or more without
a ...
Any building or portion of a building having an assembly room with an occupant
load of less than 1000 and a stage . Division 2 . 1 . Any building or portion of a
building having an assembly room with an occupant load of 300 or more without
a ...
Page 428
That portion of the structure selected for loading shall be subject to a total load ,
including dead loads already acting , equivalent to 0 . 85 ( 1 . 4D + 1 . 7L ) .
Determination of L shall include live load reductions as permitted by Section
2306 . 4 .
That portion of the structure selected for loading shall be subject to a total load ,
including dead loads already acting , equivalent to 0 . 85 ( 1 . 4D + 1 . 7L ) .
Determination of L shall include live load reductions as permitted by Section
2306 . 4 .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 19 |
Part Administrative | 25 |
201 | 28 |
Copyright | |
80 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending building official ceiling Chapter column compression computed concrete conform connections considered construction continuous covering Decking determined diameter direction distance Division doors effective elements equal equipment exceed EXCEPTION exit exterior walls face factor feet fire fire-resistive flexural floor foot forces Formula framing grade grain greater Group height horizontal inches increased installed joints lateral least length less limited liquids load located lumber masonry materials maximum metal nails noncombustible Occupancies one-hour openings parallel percent permitted placed portion pounds protected reinforcement resist roof rooms Select Structural separation shear side slab solid space span Special specified square feet steel storage story strength stress Structural Stud surface Table tension tests thickness Type U.B.C. Standard units values vertical walls welds wide width wire wood