Uniform Building Code |
From inside the book
Results 1-3 of 82
Page 51
... protected by equivalent fire - resistive construction . ( c ) Types of Occupancy Separations . Occupancy separations shall be classed as " four - hour fire - resistive , " " three - hour fire - resistive , " " two - hour fire - resis ...
... protected by equivalent fire - resistive construction . ( c ) Types of Occupancy Separations . Occupancy separations shall be classed as " four - hour fire - resistive , " " three - hour fire - resistive , " " two - hour fire - resis ...
Page 563
... protected throughout with smoke detectors , the distance may be increased to 90 feet . 2. In buildings protected throughout by an automatic sprinkler system , the distance may be increased to 110 feet . 2. All portions of unsprinklered ...
... protected throughout with smoke detectors , the distance may be increased to 90 feet . 2. In buildings protected throughout by an automatic sprinkler system , the distance may be increased to 110 feet . 2. All portions of unsprinklered ...
Page 599
... protected as specified in Section 4306. Where fire - rated walls and partitions require protected openings , the following penetrations into or through such construction are permitted : 1. Copper or ferrous pipes or conduits may ...
... protected as specified in Section 4306. Where fire - rated walls and partitions require protected openings , the following penetrations into or through such construction are permitted : 1. Copper or ferrous pipes or conduits may ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength