Every sleeping room below the fourth story shall have at least one operable
window or exterior door approved for emergency escape or ... All escape or
rescue windows from sleeping rooms shall have a minimum net clear opening of
5 .
Every sleeping room below the fourth story shall have at least one operable
window or exterior door approved for emergency escape or ... All escape or
rescue windows from sleeping rooms shall have a minimum net clear opening of
5 .
Page 547
( e ) Exits Through Adjoining Rooms . Rooms may have one exit through an
adjoining or intervening room which provides a direct , obvious and unobstructed
means of travel to an exit corridor , exit enclosure or until egress is provided from
the ...
( e ) Exits Through Adjoining Rooms . Rooms may have one exit through an
adjoining or intervening room which provides a direct , obvious and unobstructed
means of travel to an exit corridor , exit enclosure or until egress is provided from
the ...
Page 563
( d ) Exits Through Adjoining Rooms . Interior rooms may exit through adjoining
or intervening room , provided the total distance of travel through such rooms to
an exit corridor does not exceed that specified in Subsection ( c ) 1 above and is
a ...
( d ) Exits Through Adjoining Rooms . Interior rooms may exit through adjoining
or intervening room , provided the total distance of travel through such rooms to
an exit corridor does not exceed that specified in Subsection ( c ) 1 above and is
a ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 19 |
Part Administrative | 25 |
201 | 28 |
Copyright | |
80 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending building official ceiling Chapter column compression computed concrete conform connections considered construction continuous covering Decking determined diameter direction distance Division doors effective elements equal equipment exceed EXCEPTION exit exterior walls face factor feet fire fire-resistive flexural floor foot forces Formula framing grade grain greater Group height horizontal inches increased installed joints lateral least length less limited liquids load located lumber masonry materials maximum metal nails noncombustible Occupancies one-hour openings parallel percent permitted placed portion pounds protected reinforcement resist roof rooms Select Structural separation shear side slab solid space span Special specified square feet steel storage story strength stress Structural Stud surface Table tension tests thickness Type U.B.C. Standard units values vertical walls welds wide width wire wood