Uniform Building Code |
From inside the book
Results 1-3 of 42
Page 552
... stairway width is permitted . ( d ) Winding Stairways . In Group R , Division 3 Occupancies and in private stairways in Group R , Division 1 Occupancies , winders may be used if the required width of run is provided at a point not more ...
... stairway width is permitted . ( d ) Winding Stairways . In Group R , Division 3 Occupancies and in private stairways in Group R , Division 1 Occupancies , winders may be used if the required width of run is provided at a point not more ...
Page 553
... Stairway Construction . Interior stairways shall be constructed as specified in Part IV of this code . Except when enclosed usable space under stairs is prohibited by Section 3309 ( f ) , the walls and soffits of the enclosed space ...
... Stairway Construction . Interior stairways shall be constructed as specified in Part IV of this code . Except when enclosed usable space under stairs is prohibited by Section 3309 ( f ) , the walls and soffits of the enclosed space ...
Page 555
... stairway , ramp or escalator serving only one adjacent floor and not connected with corridors or stairways serving other floors . For enclosure of escala- tors serving Group B Occupancies , see Chapter 17 . 2. Stairs in Group R ...
... stairway , ramp or escalator serving only one adjacent floor and not connected with corridors or stairways serving other floors . For enclosure of escala- tors serving Group B Occupancies , see Chapter 17 . 2. Stairs in Group R ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength