Uniform Building Code |
From inside the book
Results 1-3 of 70
Page 79
Storage , handling , use or sale of hazardous and highly flammable or explosive
materials other than flammable liquids . EXCEPTION : The storage , handling ,
use or sale of hazardous materials or chemicals that do not exceed the quantities
...
Storage , handling , use or sale of hazardous and highly flammable or explosive
materials other than flammable liquids . EXCEPTION : The storage , handling ,
use or sale of hazardous materials or chemicals that do not exceed the quantities
...
Page 80
... less than 10 feet from a property line . For smoke and heat venting , see
Section 3206 . ( c ) Special Occupancies . 1 . Liquid storage rooms . The design
and construction of liquid storage rooms in which Class I , II or III - A liquids are
stored ...
... less than 10 feet from a property line . For smoke and heat venting , see
Section 3206 . ( c ) Special Occupancies . 1 . Liquid storage rooms . The design
and construction of liquid storage rooms in which Class I , II or III - A liquids are
stored ...
Page 148
When connected to , part of , or housed within a building : a . Penthouses ,
anchorage and supports for chimneys , stacks and tanks , including contents b .
Storage racks with upper storage level at more than 8 feet in height , plus
contents c .
When connected to , part of , or housed within a building : a . Penthouses ,
anchorage and supports for chimneys , stacks and tanks , including contents b .
Storage racks with upper storage level at more than 8 feet in height , plus
contents c .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 19 |
Part Administrative | 25 |
201 | 28 |
Copyright | |
80 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending building official ceiling Chapter column compression computed concrete conform connections considered construction continuous covering Decking determined diameter direction distance Division doors effective elements equal equipment exceed EXCEPTION exit exterior walls face factor feet fire fire-resistive flexural floor foot forces Formula framing grade grain greater Group height horizontal inches increased installed joints lateral least length less limited liquids load located lumber masonry materials maximum metal nails noncombustible Occupancies one-hour openings parallel percent permitted placed portion pounds protected reinforcement resist roof rooms Select Structural separation shear side slab solid space span Special specified square feet steel storage story strength stress Structural Stud surface Table tension tests thickness Type U.B.C. Standard units values vertical walls welds wide width wire wood