Page 221
... Studs shall be placed with their wide dimension perpen- dicular to the wall . Not less than three studs shall be installed at each corner of an exterior wall . EXCEPTION : At corners a third stud may be omitted through the use of wood ...
... Studs shall be placed with their wide dimension perpen- dicular to the wall . Not less than three studs shall be installed at each corner of an exterior wall . EXCEPTION : At corners a third stud may be omitted through the use of wood ...
Page 222
... studs spaced not over 16 inches on center when installed in accordance with Section 2514 and Table No. 25 - P . E. Gypsum sheathing panels not less than 1⁄2 inch thick on studs spaced not over 16 inches on center when installed in ...
... studs spaced not over 16 inches on center when installed in accordance with Section 2514 and Table No. 25 - P . E. Gypsum sheathing panels not less than 1⁄2 inch thick on studs spaced not over 16 inches on center when installed in ...
Page 620
... Studs Interior Partition with Plaster Each Side 6511 66 67 2 " x 4 " wood studs 16 " on center with % " perforated gypsum lath with 1 " hexagonal mesh of No. 20 gauge wire furred out 16 " and 1 " perlite or vermiculite gypsum plaster ...
... Studs Interior Partition with Plaster Each Side 6511 66 67 2 " x 4 " wood studs 16 " on center with % " perforated gypsum lath with 1 " hexagonal mesh of No. 20 gauge wire furred out 16 " and 1 " perlite or vermiculite gypsum plaster ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength