Welds Sec . 2714 . ( a ) General . Welder qualification requirements , welding
procedure and welding electrodes for other than sheet steel shall conform to U .
B . C . Standard No . 27 - 6 . Welder qualification requirements , welding
procedure ...
Welds Sec . 2714 . ( a ) General . Welder qualification requirements , welding
procedure and welding electrodes for other than sheet steel shall conform to U .
B . C . Standard No . 27 - 6 . Welder qualification requirements , welding
procedure ...
Page 484
The effective length of any segment of intermittent fillet welding shall be not less
than four times the weld size with a ... Side or end fillet welds terminating at ends
or sides , respectively , of parts or members shall , wherever practicable , be ...
The effective length of any segment of intermittent fillet welding shall be not less
than four times the weld size with a ... Side or end fillet welds terminating at ends
or sides , respectively , of parts or members shall , wherever practicable , be ...
Page 496
Shear on effective area FILLET WELDS 0 . 30 X nominal tensile strength of weld
metal ( ksi ) , except shear stress on base metal shall not exceed 0 . 40 x yield
stress of base metal Same as base metal Weld metal with a strength level equal
to ...
Shear on effective area FILLET WELDS 0 . 30 X nominal tensile strength of weld
metal ( ksi ) , except shear stress on base metal shall not exceed 0 . 40 x yield
stress of base metal Same as base metal Weld metal with a strength level equal
to ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 19 |
Part Administrative | 25 |
201 | 28 |
Copyright | |
80 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending building official ceiling Chapter column compression computed concrete conform connections considered construction continuous covering Decking determined diameter direction distance Division doors effective elements equal equipment exceed EXCEPTION exit exterior walls face factor feet fire fire-resistive flexural floor foot forces Formula framing grade grain greater Group height horizontal inches increased installed joints lateral least length less limited liquids load located lumber masonry materials maximum metal nails noncombustible Occupancies one-hour openings parallel percent permitted placed portion pounds protected reinforcement resist roof rooms Select Structural separation shear side slab solid space span Special specified square feet steel storage story strength stress Structural Stud surface Table tension tests thickness Type U.B.C. Standard units values vertical walls welds wide width wire wood