Uniform Building Code |
From inside the book
Results 1-3 of 11
Page 216
... wood stud walls shall be covered on the outside with the materials and in the manner specified in this section or ... Shingles or shakes . Wood shingles or shakes and asbestos cement shingles may be used for exterior wall covering ...
... wood stud walls shall be covered on the outside with the materials and in the manner specified in this section or ... Shingles or shakes . Wood shingles or shakes and asbestos cement shingles may be used for exterior wall covering ...
Page 534
... Wood shingles . Shingles may be applied to roofs with solid or spaced sheathing . Shingles shall be laid with a side lap of not less than 11⁄2 inches between joints in adjacent courses , and not in direct alignment in alternate courses ...
... Wood shingles . Shingles may be applied to roofs with solid or spaced sheathing . Shingles shall be laid with a side lap of not less than 11⁄2 inches between joints in adjacent courses , and not in direct alignment in alternate courses ...
Page 537
... Wood shingles . Special purpose wood shingle roofing shall conform to grading and application requirements of this chapter . In addition , the deck , whether of spaced boards or solid , shall be overlaid with a layer of approved ...
... Wood shingles . Special purpose wood shingle roofing shall conform to grading and application requirements of this chapter . In addition , the deck , whether of spaced boards or solid , shall be overlaid with a layer of approved ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength