... Chimneys Masonry Chimneys 3704. Terra Cotta Chimneys 3705. Metal Smokestacks 3706. Smoke Pipes 3707 . Fireplaces 3708. Gas Vents 3709 . 3710 . CHAPTER 38 . SEC . 3801 . 3802 . Protection of Combustible Construction Incinerators Fire ...
... Chimneys Masonry Chimneys 3704. Terra Cotta Chimneys 3705. Metal Smokestacks 3706. Smoke Pipes 3707 . Fireplaces 3708. Gas Vents 3709 . 3710 . CHAPTER 38 . SEC . 3801 . 3802 . Protection of Combustible Construction Incinerators Fire ...
Page 210
... CHIMNEYS , VENTS AND FIREPLACES Sec . 3701. ( a ) Scope . Chimneys , fireplaces , flues and vents carrying products of combusion , and their connections , shall conform to the requirements of this chapter . ( b ) Appliances . See ...
... CHIMNEYS , VENTS AND FIREPLACES Sec . 3701. ( a ) Scope . Chimneys , fireplaces , flues and vents carrying products of combusion , and their connections , shall conform to the requirements of this chapter . ( b ) Appliances . See ...
Page 212
... chimneys shall be protected by four inches ( 4 ′′ ) of incombusti- ble material in the bottom of the flue . Sec ... chimneys or smokestacks . ( b ) Materials . Every smoke pipe connecting a fire box or combustion chamber with a chimney ...
... chimneys shall be protected by four inches ( 4 ′′ ) of incombusti- ble material in the bottom of the flue . Sec ... chimneys or smokestacks . ( b ) Materials . Every smoke pipe connecting a fire box or combustion chamber with a chimney ...
Contents
Civil Engine 8 ply 16 Me Ciurg 1946 ld | 19 |
Part IIDefinitions and Abbreviations | 29 |
CHAPTER | 36 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts brick Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange flat slab foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permitted piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe solid space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood