... Separation . Occupancy separations Mixed shall be classed as " Absolute , " " Special " and " Ordinary . " Occupancy 1. An " Absolute Occupancy Separation " shall have no open- ( Cont'd . ) ings therein and shall be of not less than ...
... Separation . Occupancy separations Mixed shall be classed as " Absolute , " " Special " and " Ordinary . " Occupancy 1. An " Absolute Occupancy Separation " shall have no open- ( Cont'd . ) ings therein and shall be of not less than ...
Page 37
... SEPARATIONS IN BUILDINGS OF MIXED OCCUPANCY Legend : A - Absolute Separation . S - Special Separation . N - No Separation . O - Ordinary Separation . Chapter Refer- Group B C D E F G H I J ence 6 A N 7 B ZZ N N 8 C ZZZ N N N 9 D SSON ...
... SEPARATIONS IN BUILDINGS OF MIXED OCCUPANCY Legend : A - Absolute Separation . S - Special Separation . N - No Separation . O - Ordinary Separation . Chapter Refer- Group B C D E F G H I J ence 6 A N 7 B ZZ N N 8 C ZZZ N N N 9 D SSON ...
Page 57
... Separation . " Exceptions : 1. Such furnaces may be used without an " Occupancy Separation " in buildings not more than two stories in height . 2. In buildings of Type V construction an " Ordinary Occupancy Separation " may be used ...
... Separation . " Exceptions : 1. Such furnaces may be used without an " Occupancy Separation " in buildings not more than two stories in height . 2. In buildings of Type V construction an " Ordinary Occupancy Separation " may be used ...
Contents
Civil Engine 8 ply 16 Me Ciurg 1946 ld | 19 |
Part IIDefinitions and Abbreviations | 29 |
CHAPTER | 36 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts brick Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange flat slab foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permitted piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe solid space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood