Uniform Building CodePacific Coast Building Officials Conference, 1927 - Building laws |
From inside the book
Results 1-3 of 62
Page
... Enclosure of Vertical Openings Fire Extinguishing Apparatus Special Hazards 607 . 608 . 609 . 610 . Exceptions and Deviations Mixed Occupancies CHAPTER 7. Requirements for Group B Buildings ...... 26 SEC . 701. Group B Occupancies ...
... Enclosure of Vertical Openings Fire Extinguishing Apparatus Special Hazards 607 . 608 . 609 . 610 . Exceptions and Deviations Mixed Occupancies CHAPTER 7. Requirements for Group B Buildings ...... 26 SEC . 701. Group B Occupancies ...
Page
... Enclosure of Vertical Openings 1107. Fire Extinguishing Apparatus 1108. Special Hazards 1109. Exceptions and Deviations 1110. Mixed Occupancies CHAPTER 12. Requirements for Group G Buildings ...... 43 SEC . 1201. Group G Occupancies ...
... Enclosure of Vertical Openings 1107. Fire Extinguishing Apparatus 1108. Special Hazards 1109. Exceptions and Deviations 1110. Mixed Occupancies CHAPTER 12. Requirements for Group G Buildings ...... 43 SEC . 1201. Group G Occupancies ...
Page 155
... Enclosure Walls Sec . 2939. Panel and enclosure walls in skeleton framed Panel and buildings shall be not less than eight ( 8 ) inches thick if of solid Enclosure brick , hollow clay tile , concrete block or tile , plain concrete or ...
... Enclosure Walls Sec . 2939. Panel and enclosure walls in skeleton framed Panel and buildings shall be not less than eight ( 8 ) inches thick if of solid Enclosure brick , hollow clay tile , concrete block or tile , plain concrete or ...
Other editions - View all
Common terms and phrases
asbestos balconies bars beams block or tile brick Building Inspector building or structure cent Chapter 43 chimney Code column combustible compression compression member construction as specified doors Douglas Fir dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders Group A buildings Group H Gunite gypsum height horizontal inches in thickness inches thick incombustible materials joists less than one-hour less than three live load located masonry walls maximum metal mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Pondosa Portland cement pounds per square proscenium protected ramps reinforced concrete rivets seats side slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet square inch Stairs and Exits stairways stories street structural steel studs supported thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood